1.
  • Båth, Magnus, 1974, et al. (author)
  • Investigation of image components affecting the detection of lung nodules in digital chest radiography
  • 2005
  • In: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 1605-7422. ; 5749, s. 231-242
  • Journal article (other academic/artistic)abstract
    • The aim of this work was to investigate and quantify the effects of system noise, nodule location, anatomical noise and anatomical background on the detection of lung nodules in different regions of the chest x-ray. Simulated lung nodules of diameter 10 mm but with varying detail contrast were randomly positioned in four different kinds of images: 1) clinical images collected with a 200 speed CR system, 2) images containing only system noise (including quantum noise) at the same level as the clinical images, 3) clinical images with removed anatomical noise, 4) artificial images with similar power spectrum as the clinical images but random phase spectrum. An ROC study was conducted with 5 observers. The detail contrast needed to obtain an Az of 0.80, C0.8, was used as measure of detectability. Five different regions of the chest x-ray were investigated separately. The C0.8 of the system noise images ranged from only 2% (the hilar regions) to 20% (the lateral pulmonary regions) of those of the clinical images. Compared with the original clinical images, the C0.8 was 16% lower for the de-noised clinical images and 71% higher for the random phase images, respectively, averaged over all five regions. In conclusion, regarding the detection of lung nodules with a diameter of 10 mm, the system noise is of minor importance at clinically relevant dose levels. The removal of anatomical noise and other noise sources uncorrelated from image to image leads to somewhat better detection, but the major component disturbing the detection is the overlapping of recognizable structures, which are, however, the main aspect of an x-ray image.
  •  
2.
  • Hemdal, Bengt, et al. (author)
  • Can the average glandular dose in routine digital mammography screening be reduced? A pilot study using revised image quality criteria.
  • 2005
  • In: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 383-8
  • Journal article (peer-reviewed)abstract
    • There is a need for tools that in a simple way can be used for the evaluation of image quality related to clinical requirements in mammography. The aim of this work was to adjust the present European image quality criteria to be relevant also for digital mammography images, and to use as simple and as few criteria as possible. A pilot evaluation of the new set of criteria was made with mammograms of 28 women from a General Electric Senographe 2000D full-field digital mammography system. One breast was exposed using the standard automatic exposure mode, the other using about half of that absorbed dose. Three experienced radiologists evaluated the images using visual grading analysis technique. The results indicate that the new quality criteria can be used for the evaluation of image quality related to clinical requirements in digital mammography in a simple way. The results also suggest that absorbed doses for the mammography system used may be substantially reduced.
  •  
3.
  • Hemdal, Bengt, et al. (author)
  • Clinical evaluation of a new set of image quality criteria for mammography.
  • 2005
  • In: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 389-94
  • Journal article (peer-reviewed)abstract
    • The European Commission (EC) quality criteria for screen-film mammography are used as a tool to assess image quality. A new set of criteria was developed and initially tested in a previous study. In the present study, these criteria are further evaluated using screen-film mammograms that have been digitised, manipulated to simulate different image quality levels and reprinted on film. Expert radiologists have evaluated these manipulated images using both the original (EC) and the new criteria. A comparison of three different simulated dose levels reveals that the new criteria yield a larger separation of image criteria scores than the old ones. These results indicate that the new set of image quality criteria has a higher discriminative power than the old set and thus seems to be more suitable for evaluation of image quality in mammography.
  •  
4.
  • Tingberg, Anders, et al. (author)
  • Detectability of pathological lesions in lumbar spine radiography
  • 2005
  • In: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 1605-7422. ; 5749, s. 518-526
  • Journal article (other academic/artistic)abstract
    • Thirty images with added simulated pathological lesions at two different dose levels (100% and 10% dose) were evaluated with the free-response forced error experiment by nine experienced radiologists. The simulated pathological lesions present in the images were classified according to four different parameters: the position within the lumbar spine, possibility to perform a symmetrical (left-right) comparison, the lesion contrast, and the complexity of the surrounding background where the lesion was situated. The detectability of each lesion was calculated as the fraction of radiologists who successfully detected the lesion before a false positive error was made. The influence of each of the four parameters on lesion detectability was investigated. The results of the study show that the influence of lesion contrast is the most important factor for detectability. Since the dose level had a limited effect on detectability, large dose savings can be made without reducing the detectability of pathological lesions in lumbar spine radiography.
  •  